Taylor 050771-m Double Oven User Manual


 
1
Models 904/906
To the Installer
050830
Section 1 To the Installer
Installation
This unit must be installed with the four 4” metal legs
mounted to the base of the unit. These legs are
provided wit h the oven. Remove t he legs from the
packaging found in the oven cavity, and cap them with
the rubber boots (also found in the oven cavity). Mount
the legs into the four holes on the bottom of the unit.
For proper balancing, level the unit left to right and front
to back b y adjusting the legs.
This machine is designed for indoor use only.
Air Clearance
The oven requires a minimum of 1 ” (25 mm) clearance
around all s ides, and 4” (102 m m) clearance on the
bottom to allow for adequate air circulation.
Electrical Connections
This equipment is supplied with a 3-wire cord and
grounding type plug for connection to a s ingle phase,
60 cycle, branch circuit supply. This unit must be
plugged into a properly grounded receptacle. An
appropriate receptacle is supplied with the oven and is
packaged with the cooking trays.
THESE OVENS ARE NOT FOR HO USEHOLD USE.
The rated current for the Model 904 is 16 amp.;
therefore the wall outlet must be rated for 20 amps on
a dedicated circuit. The rated current for the Model 906
is 15 amp. for 208/60/1 and 12.5 amp. for
220-240/60/1; therefore the wall outlet must be rated
for 15 amps on a dedicated circuit. Use the outlet
receptacle provided with the oven.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
In the United States, this equipment is intended to be
installed in a ccordance with the National Electrical
Code (NEC), ANSI/NFPA 70--1987. The purpose of
the NEC code is the practical safeguarding of persons
and property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. Compliance therewith and
proper maintenance will result in an installation
essentially free from hazard!
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
Stationary appliances which are not equipped with a
power cord and a plug or other device to disconnect
the appliance from the power source must have an
all--pole disconnecting device with a contact gap of at
least 3 mm installed i n the ex ternal installation.