Taylor RD30 Refrigerator User Manual


 
18
Models RD30/RC25Operating Procedures
081029
Place the control switch in the “WASH” position. Press
the fill switch to activate the mix solenoid. The mix
solenoid willremain openuntil the mixlevel float switch
is satisfied. Drain sanitizer from the freezing cylinder
and repeat this procedure until full strength solution is
dispensed from the mix delivery container . Make sure
all sanitizer is removed from the fill system. Place the
fill switch inthe “OFF” positionand drain anyremaining
solution from the freezing cylinder .
Figure 25
For units equipped with a post mix valve, the
following procedure is to be used in place of Step
1 of the Sanitizing Procedure.
Prepare a pail of approved 100 PPM cleaning solution
(examples: 2--1/2 gal. [9.5 liters] of Kay--5R or 2 gal.
[7.6 liters] of Stera--SheenR). USE WARM WATER
AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS. Pour the s olution into a clean,
empty mix delivery system container.
Figure 26
Place the control switch in the “WASH” position. Place
the “FILL” switch in the “ON” position. To prime the fill
valve, press and hold the area marked “PUSH” on the
front of the post mix valve (prime button). After 10
seconds, release the valve and the cleaning solution
will c ontinueto flowuntilthe mixfloat issatisfied or until
the fill switch is turned to the “OFF” position.
Figure 27
Note: If the cleaning solution does not continue to
flow after releasing the prime button, press and hold
the prime button for an additional ten (10) seconds.
Repeat this procedure as required to prime the post
mix valve.
Figure 28
Drain the sanitizer from the freezing cylinder and
repeat this procedure until all the cleaning solution is
dispensed from the mix delivery container. Disconnect
the mix delivery container.
Figure 29