Models RD30/RC25 Operating Procedures
081029
Step 2
Dispenser. Prepare a pail of approved 100 PPM
sanitizing solution (examples: 2--1/2 gal. [9.5 liters] of
Kay--5R or 2 gal. [7.6 liters] of Stera--SheenR). USE
W ARM WATER AND FOLLOW THE MANUFACTUR-
ER’S SPECIFICATIONS. Remove the upper rear
cover, and open the hopper cover . Pour the sanitizing
solution into the hopper and allow the solution to flow
into the freezing cylinder.
Figure 30
Step 3
Once the mix float switch is submerged in the
sanitizing solution, brush clean the mix hopper , mix
inlet hole, and mix level float switch.
Figure 31
Step 4
Place the control switch in the “WASH” position. This
will cause the sanitizing solution in the freezing
cylinder to be agitated. Allow the solution to agitate for
five minutes.
Figure 32
Step 5
Place thecontrolswitch inthe “ OFF” position. Place a n
empty mix pail beneath the door spout. Open the draw
valve and draw off all of the sanitizing solution. When
the sanitizer stops flowing from the door spout, close
the draw valve.
Figure 33
Step 6
Replace the hopper cover and the upper rear cover.
Figure 34