English 12
Installation
Electrical Installation
All model ovens on the front cover are dual rated, designed
to be connected to either 208/240V AC, 60 Hz, 4 wire,
single-phase power supply.
The electrical supply should be a 4-wire single-phase AC.
Install a suitable conduit box (not furnished). An
appropriately-sized, UL-listed conduit connector must be
used to correctly attach the conduit to the junction box.
Important: Local Codes may vary; installation, electrical
connections and grounding must comply with all applicable
local codes.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and the
bare ground wire from the oven to the white neutral
electrical supply wire.
Electrical Connection
The four-wire connection is preferred, but where local
codes permit, the three wire connection is also acceptable.
Four-wire Connection
• Connect the red oven wire to the red electrical supply
wire (hot wire).
• Connect the black oven wire to the black electrical
supply wire (hot wire).
• Connect the white neutral oven wire to the white
neutral (not bare ground) electrical supply wire.
• Connect the bare ground oven wire to the bare ground
electrical supply wire.
Three-wire Connection
• Connect red wire from oven to red wire injunction box.
• Connect black wire from oven to black wire in junction
box.
• Connect both green ground wire and white wire from
oven to white (or gray) neutral wire in junction box.
The conduit cable, where connected at the oven, swivels.
Rotate conduit cable upward (or downward) and direct
through hole prepared in cabinet to attach to J-Box.
To maintain serviceability, the flex conduit must not be
shortened and should be routed to permit temporary
removal of the oven.
Model Circuit Required
208V, 60 Hz 240V, 60 Hz
M301 25 AMP 30 AMP
ME301, ME271,
POD301
30 AMP
ME302,
MED302,
MED272,
PODC302
40 AMP
PODM301,
PODMW301,
MEMC301,
MEMCW301,
MEMCW271
50 AMP