Thermador MEMCW271 Oven User Manual


 
English 3
Dimensions for 27”
Wall-Mounted Units
Single Oven 27”
It is good practice, when oven is installed at the end of a
cabinet run, adjacent to a perpendicular wall or cabinet
door, to allow at least 1/4” space between the side of the
oven and the wall/door.
For oven support, install 2x4’s extending front to back flush
with the bottom and the side of the opening. The supporting
base must be well secured to the floor/cabinet and level.
Note:
The conduit box must be installed either above or below
the unit. If the conduit box is installed below the unit, a 2”
diameter hole or space is required between the back wall
and the right rear of the 2x4 supports.
The cabinet base must be flat and capable of supporting a
weight of at least 193 lbs (87 kg).
Double Oven 27”
It is good practice, when oven is installed at the end of a
cabinet run, adjacent to a perpendicular wall or cabinet
door, to allow at least 1/4” space between the side of the
oven and the wall/door.
For oven support, install 2x4’s extending front to back flush
with the bottom and the side of the opening. The supporting
base must be well secured to the floor/cabinet and level.
Note:
The conduit box must be located above the unit to facilitate
connecting and servicing.
The cabinet base must be flat and capable of supporting a
weight of at least 361 lbs (164 kg).
27 1/16”
(687mm)