FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. KEEP THE
APPLIANCE AREA CLEAR AND FREE FROM COMBUSTIBLES.
AIR SUPPLY
Provisions for adequate air supply must be provided.
AIR INTAKES IN BOTTOM
Make certain that the air intake opening in the bottom of the appliance is not obstructed.
It is essential for proper combustion and operation of the appliance.
CAUTION
DO NOT USE SPACE UNDER FRYER FOR STORAGE
LEVELING UNIT
Level unit by adjusting the (4) feet.
CAUTION
DO NOT INSTALL WITHOUT FEET PROVIDED.
CLEARANCE
Clearances from combustible and non-combustible material must be a minimum of 48" from the
top of the appliance and 6" from the sides and back. Adequate clearance should also be provided
for proper operation and servicing.
EXHAUST CANOPY
It is essential that facilities be provided over the fryer to carry off fumes and gases.
This unit is not to be connected to a ue or stack for exhaust purposes.
GAS PIPING
Gas piping shall be new, clean and of such size and so installed as to provide a supply of gas
sufcient to meet the full gas input of the appliance. If the appliance is to be connected to existing
piping, it shall be checked to determine if it has adequate capacity. Joint compound (pipe dope)
shall be used sparingly and only on the male threads of the pipe joints. Such compounds shall be
resistant to the action of L.P. gases.
WARNING: Any loose dirt or metal particles which are allowed to enter the gas lines
on the appliance will damage the automatic valve and affect its operation. When
installing this appliance, all pipe and ttings must be free from all internal loose dirt.
Do not remove the seal until actual connection is made to the gas supply line.
CONNECTING GAS SUPPLY LINE
The gas inlet on this appliance is sealed at the factory to prevent entry of dirt. Do not remove
this seal until actual connection is made to the gas supply line. Each unit is supplied with a
gas pressure regulator adjusted for use with the gas specied on the nameplate. To connect
gas supply, attach pipe nipple provided with unit. For pressure requirements and adjustment of
regulator, see GAS PRESSURE REGULATOR.
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed upstream from the union and within six feet of the
appliance.
CHECKING FOR GAS LEAKS
Soap and water solution or other material acceptable for the purpose of locating gas leaks shall
be used. MATCHES, CANDLES, FLAME OR OTHER SOURCES OF IGNITION SHALL NOT BE
USED FOR THIS PURPOSE.