II. RECEIPT INSPECTION
All Traulsen products are factory tested for performance
and are free from defects when shipped. The utmost care
has been taken in crating this product to protect against
damage in transit.
You should carefully inspect your unit for damage during
delivery. If damage is detected, you should save all the
crating materials and make note on the carrier’s Bill Of
Lading describing the damage. A freight claim should be
led immediately. If damage is subsequently noted dur-
ing or immediately after installation, contact our customer
care team to le a freight claim. There is a fteen (15)
day limit to le freight damage with the carrier. Under no
condition may a damaged unit be returned to Traulsen
without rst obtaining written permission (return autho-
rization). You may contact Hobart/Traulsen customer
care at 800-333-7447 to request a return or le a claim.
III. a - LOCATION:
Select a proper location for your unit, away from extreme
heat or cold.
III. b - PACKAGING:
Your Traulsen unit is shipped from the factory bolted to a
sturdy wooden pallet in stretch wrapped material.
Most exterior stainless steel surfaces have a protective
vinyl covering to prevent scratching during manufactur-
ing, shipping and installation. After the unit is installed
in place of application peel, remove and discard the
covering from all surfaces.
To remove the wooden pallet, rst if at all possible, we
suggest that the cabinet remain bolted to the pallet dur-
ing all transportation to the point of nal installation. The
bolts can then be removed with a 1/2” socket wrench.
Avoid laying the unit on its back for removal of the pallet.
NOTE: Traulsen does not recommend laying the unit
on its back. If you must, please allow the unit to re-
main in an upright position for 24 hours before plug-
ging it in so that the compressor oils and refrigerant
may settle.
III. c - INSTALLING/ADJUSTING LEGS OR
CASTERS:
Casters are installed at the factory but will require adjust-
ment upon installation.
To adjust the legs or casters, loosen the two bolts and
move leg or caster to desired location, spacing between
leg or caster not to exceed 48 inches. Leg or caster on
each end of the unit can not exceed 8 inches from the
end of the cabinet.
III. INSTALLATION
III. INSTALLATION (continued)
III. c - INSTALLING/ADJUSTING LEGS OR CASTERS:
III. d - CORD & PLUG:
All self-contained models are shipped standard with a NEMA
5-15P plug and 9 foot cord . Select only a dedicated electrical
outlet for power source.
NOTE: Do not under any circumstances, cut or remove the
round grounding prong from the plug, or use an extension
cord.
III. e - POWER SUPPLY:
The supply voltage should be checked prior to connection to
be certain that proper voltage for the cabinet wiring is available
(refer to the serial tag to determine correct unit voltage, see page
1). Make connections in accordance with local electrical codes.
Use qualied electricians.
Use of a separate, dedicated circuit is required. Size wiring to
handle indicated load and provide necessary over current protec-
tor in circuit (see amperage requirements on the unit’s serial tag).
IV. a - TEMPERATURE CONTROL:
The temperature is set at the factory but local conditions may
necessitate slight adjustment.
The temperature control is located behind the silver plug on the
front side of the system area (dial thermometer side). To adjust,
remove the plug turn the adjustment screw with a pair of pliers
a small amount at a time; turning clockwise lowers the tempera-
ture. An “OFF” position is fully counterclockwise and interrupts
power to the compressor and condenser fan only, not the entire
refrigerator.
IV. OPERATION