Traulsen R & A Series Refrigerator User Manual


 
-18-
VII. INTELA-TRAUL
®
(continued)
VII. p - ADJUSTING THE DOOR PERIMETER HEATERS:
This parameter allows the customer to turn ON and OFF the anti-condensate door perimeter heaters.
This parameter is set to the highest setting (100) at the factory so that the door heaters stay on continu-
ously. If you choose to have the door heaters cycle on and off, lower this parameter to approximately 30.
If condensation forms around the doors, increase the parameter until condensation stops. The exact
setting will vary depending on ambient conditions. This feature is not available on undercounter mod-
els.
Follow the instructions to enter the customer access code on page 11. When the control displays
Thermostat Set High, press the down arrow key until the control display reads
DewPoint Compensation Factor. Press the set button . Press the arrow keys to
adjust the factor to your desired setting. When the display shows the factor you want press the set
button . The display will then read Thermostat Set Point High. You can use the up or
down arrow keys to scroll to the next parameter or press the alarm cancel button to exit
.
VII. q - ADJUSTING THE ROOM TEMPERATURE OFFSET:
The room temperature offset parameter allows a service technician or end user the ability to have the
display show a temperature that is within three degrees of the actual temperature being read by the
cabinet air sensor. This allows for continuity of reading between different temperature reading devices.
(i.e.: thermistor Vs thermocouple Vs handheld thermometer) This parameter is preset at the factory to
“0” or no offset.
Follow the instructions to enter the customer access code on page 11. When the control displays
Thermostat Set High, press the down arrow key until the control display reads
Room Temperature Offset. Press the set button . Use the arrow keys to adjust the
offset to your desired setting. When the display shows the offset you want press the set button .
The display will then read Thermostat Set Point High. You can use the up or down arrow
keys to scroll to the next parameter or press the alarm cancel button to exit .
SET
SET
)
)
)
SET
SET
)
)
)