Traulsen R & A Series Refrigerator User Manual


 
VII. r - SETTING THE AUDIBLE ALARM STYLE:
This parameter will allow the customer to turn on/off the audible alarm feature on the
INTELA-TRAUL
®
control. The audible alarm is preset from the factory to OFF. The customer can choose
between an audible alarm that sounds for 3 seconds then automatically turns off, or a
continuous audible alarm that must be manually acknowledged. Regardless of this feature’s setting,
visual alarm text will display when conditions warrant.
To adjust this setting, follow the instructions to enter the customer access code on page 11. When
the control displays Thermostat Set Point High, press the up arrow key until the dis-
play reads Audible Alarm Style. Press the set button . The display will read
OFF. Use the arrow keys to scroll between for the 3-Second Audible Alarm Burst
or for Continuous Audible Alarm. When the display shows your choice of style, press the set
button . The display will then read thermostat Set Point High. Use the arrow keys
to scroll to the next parameter or press the Alarm Cancel Button to exit.
VII. s - VIEWING SENSOR TEMPERATURES:
These parameters allow a service technician or customer to view the temperature of all sensors
within the unit. The temperatures cannot be adjusted.
Follow the instructions to enter the customer access code on page 11. When the control displays
Thermostat Set Point High , press the DOWN arrow key unit the display reads
Evaporator Coil Sensor or Disharge Line Sensor or press the SET button .
The display will read Thermostat Set Point High .
Press the UP or DOWN arrow keys to scroll through the parameters or press the ALARM
CANCEL button to exit.
VII. INTELA-TRAUL
®
(continued)
-19-