-8-
VII. SPECIALTY PRODUCTS - PROOFER/PROOFER RETARDER MODELS (cont’d)
VII. d - RETARDER OPERATION (cont’d):
MANUAL OPERATION - The Traulsen proofer retarder
can also be used in either PROOF or RETARD mode,
regardless of what the 24-hour timer is set for. By
switching manually to PROOF or RETARD, the cabi-
net can be run as needed without disturbing the pre-
set schedule you have the 24-hour timer set for.
VII. e - CARE OF WATER TANK & HEATING ELEMENTS:
The automatic flush system on the Traulsen proof cabi-
net will help minimize the amount of cleaning neces-
sary to maintain an accurate and consistent operation
of this cabinet. Because water conditions vary from
location to location, we recommend that the tank cover
be removed and the interior of the water tank, along
with the heating elements, be cleaned with a soft ny-
lon bristled brush. We recommend cleaning twice a
year or as conditions dictate. Replace tank cover be-
fore placing proof cabinet back into operation. If your
area has extremely hard water, a local water treatment
expert should be consulted. It is important to note
that after treatment the water should not be deionized.
A simple zeolite conditioner is usually the best sys-
tem. Use of an in-line cartridge will reduce the fre-
quency of cleaning the heating coil, but remember to
frequently replace the cartridge.
VII. f -
INTERIOR ARRANGEMENTS:
Traulsen proofer and proofer retarder models are de-
signed to accommodate roll-in bakery racks. See be-
low for size and capacities.
Model PRI132H can accommodate one (1) roll-in rack
with a maximum size, with wheels inboard of frame, of
27” wide by 29” deep by 72” high.
Model PRI232H can accommodate two (2) standard 18”
x 26” pan racks or two (2) 23” x 23” donut screen racks.
Model PRI332H can accommodate three (3) standard
18” x 26” pan racks or two (2) 23” x 23” donut screen
racks.
Model PRR232HUT can accommodate two (2) standard
18” x 26” pan racks or two (2) 23” x 23” donut screen
racks.
The Proofer/Retarder Control
The Proofer Control
White
“Thermostat
Indicator”
Light
Green
“Water Level”
Light
WATER
LEVEL
BLOWER
ON OFF
CONTROL
TEMP
OFF
TEMPERATURE PM TIME
FLUSH
FLUSH MINUTE
HOUR
Traulsen
HUMIDISTAT
102.5 F 11:30
LOWER LEVEL TROUBLE
Amber
“Lower Level”
Light
Red
“Trouble”
Light
White
“Humidistat
Indicator”
Light
Thermostat
Flush Time
&
Time of Day
Adjustment
Ports
Humidistat
Control
Blower
ON/OFF
Switch
Blower
Power
Switch
“Flush
Indicator”
Light
Green
“Water Level”
Light
White
“Humidistat
Indicator”
Light
Amber
“Lower Level”
Light
White
“Thermostat
Indicator”
Light
Thermostat
Flush Time
&
Time of Day
Adjustment
Ports
Humidistat
Control
Delay
Bypass
Switch
Mode
Switches
OFF
HUMIDISTAT
TEMPERATURE PM TIME
FLUSH
FLUSH MINUTE
HOUR
Traulsen
102.5 F 11:30
DELAY
BYPASS
ON OFF
CONTROL
Red
“Trouble”
Light