III. INSTALLATION (continued)
III. k - BUILT-IN INSTALLATION:
Select a proper location for your unit away from ex-
treme heat or cold. Due to the unique air flow of the
unit, the Spacesaver can be built-in or used as a free-
standing unit. Allow enough clearance between the
unit and side wall so that the doors can be opened a
minimum of 90 degrees. The floor should be level,
firm and capable of supporting the weight of the fully
loaded unit.
Follow the typical installation instructions outlined in
Section III. a thru III. j as required.
All built-in units require a minimum of 1/2 clearance
around the cabinet for servicing (see figure 5). If top
clearance exceeds 1 the unit must be blocked per
the free-standing instructions of Figure 6.
NOTE: If a self-contained unit is to be installed com-
pletely recessed, the front louvers must NOT be
blocked or replaced with a solid panel. The front lou-
vers allow good air circulation in the compressor com-
partment.