IX. TROUBLE SHOOTING GUIDE
FIND YOUR PROBLEM HERE REMEDY
1. Condensing unit fails to start. a. Check if line has been disconnected.
b. Check switch behind louvers.
2. Condensing unit operates for a. Are doors closing properly?
prolonged periods or continuously. b. Dirty condenser or filter. Clean properly.
c. Evaporator coil iced. Needs to defrost.
3. Food compartment is too warm. a. Thermostat setting too high, readjust
thermostat.
b. Check door gasket for proper seal.
c. Frequent door openings, allow adequate recovery
time.
d. Perhaps a large quantity of food has
recently been added or the door was kept
open for a long period of time, in both
cases, allow adequate time for the cabinet
to recover its normal operating temperature.
4. Food compartment is too cold. a. Adjust the thermostat to a warmer
setting.
5. Condensation on the exterior surface. a. Condensation on the exterior surface of the
unit is perfectly normal during periods of
high humidity. Turn on the defogger switch.
b. Check door alignment and gaskets for
proper seal.
6. Compressor hums but does not start. a. Call service.
7. Light bulb is not functioning. a. Check if light bulb is burned out.
b. Check to see if light switch is on (if applicable).
VIII. OTHER (cont’d)
VIII. b - SPARE PARTS:
Spare or replacement parts may be obtained through
a parts supplier or one of our authorized service
agents. A complete list of authorized service agents
accompanies this manual and is also posted on our
company's official website @ www.traulsen.com.
VIII. c -
WARRANTY REGISTRATION:
For your convenience, the warranties on your new
Traulsen unit may be registered with us by one of two
methods. Completing the enclosed warranty card
(shipped with the unit), or by filling out the on-line
warranty registration form located on the Technical
Service page of our website (www.traulsen.com).