Tricity Bendix TBC 650 BL Range User Manual


 
Instructions for the Installer
Please examine the appliance for any damage. If the
appliance is damaged contact your retailer before the
appliance is connected.
Please keep packaging away from children and dis-
pose of with due regard for the environment.
Technical Data
TBC 650 BL
Hob dimensions:
length: 572 mm
depth: 502 mm
height: 49 mm
Cut out dimensions:
length: 560 mm
depth: 490 mm
Voltage 230 V - 50 Hz
Cable 6 mm
Total power: 5,8 kW
Fuse rating 30 Amp
We reserve the right to make technical changes.
Important Safety Requirements
.The hob must only be installed by a qualified electri-
cian.
.Damaged hobs with cracks or breakages in the
ceramic glass surface must not be connected to the
electrical supply.
.This hob must be installed in accordance with the
IEE Wiring Regulations (current Edition). Detailed
recommendations are contained in the following
British Standards Codes of Practice: B.S.
6172/B.S. 5440 Part 2 and B.S. 6891 Current Edi-
tions.
Installation dimensions
The opening in the cabinet must correspond to the
standard dimensions. The necessary information can
be found in the dimensional sketch.
.The separation between the lower surface of the
hob and the parts of the furniture below it must be
at least 20 mm
.The lateral separation between the sides of the hob
and the cabinet must be at least 55 mm, and must
be at least 55 mm from the rear panel.
20 mm
min 55 mm
20 mm
min 55 mm
distance from worktop opening to
the left or right side wall or to a hig-
h cupboard
distance from worktop
opening to the rear wall
MADE IN GERMANY
TYP: PEE2 001 PNC: 949 590 770 MODEL: TBC 650 BL
AC 230 V
Total max. 5.8 kW
F.Nr.: . . . . . . . . . . . .