.The minimum distance combustiblematerial canbe
fitted above the hob in line with the edges of the hob
is 420 mm. If it is fitted below 420 mm a space of 55
mm must be allowed from the edges of the hob.
.The minimum distance combustiblematerial canbe
fitted directly above the hob is 700 mm.
.If a cooker hood is installed above the hob, a clea-
rance height of 650 mm must be allowed.
This appliance conforms to Type Y (IEC 335-2-6)
with regard to fire protection. Only appliances of
this type may be installed on one side of adjacent
cabinets or walls.
Installation
.Cut the worktop according to the prescribed dimen-
sions. See fig. 1. Saw exactly along the scribedline.
.Place according to figure 2.
Fastening according to fig. 3
.Tighten bracket against the underside of the work-
top. Fix according to figur 3.
.Using a screwdriver, tighten the tension clamps
evenly starting at the centre and moving diagonally
until the built-in rim is tight on the worktop.
.Do not over tighten.
.Do not use an electric or pneumatic screwdriver
without an adjustable safety clutch.
Points for fixing clamps
490 +1560
+1
R5
560 + 1
490 + 1
R5
radius
radius
width
depth
fig 1
fig 2
fig 3
hobsframe
Ceramicglass plate
worktop
fixing clamp
Einbaukasten
min. 650 mm