Tricity Bendix TBDW 32 Dishwasher User Manual


 
6
Audible signals
Audible signals have been introduced to help
indicate which operations the dishwasher is
performing.
- end of the washing programme,
- malfunction of the appliance.
Factory setting: audible signals activated.
Deactivation/activation of the audible signals
2.Press and hold
Programme/Cancel
button until
programme light 1
flashes and
programme light 2
illuminates with fixed
light.
6.To memorise the
operation, switch off
the dishwasher by
pressing the On-Off
button.
3.Press
Programme/Cancel
button again:
programme light 1
becomes fixed and
programme light 2
starts flashing.
1.The dishwasher must
be switched off.
Switch on the
dishwasher by
pressing the On-Off
button.
4.After a few seconds
programme light 1
turns off, programme
light 2 goes on
flashing and End light
illuminates with fixed
light.
The illumination of the
End light means that
the audible signals
are active.
5.To deactivate the
audible signals, press
the Programme/-
Cancel button, the
End light turns off
indicating that the
audible signals have
been deactivated.
7.To reactivate again the
audible signals, follow
the instructions till point
4. Wait a few seconds
and then press the
Programme/-Cancel
button, the End light
illuminates indicating
that the audible signals
have been reactivated.
117996 79/0en 4-07-2006 18:03 Pagina 6