U-Line 15WC Refrigerator User Manual


 
www.U-LineService.com 10 02/2005
15R and 15WC Models
Electrical Specifications
CAUTION
Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current).
An individual, properly grounded branch circuit or circuit
breaker is recommended. GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be
sure to consult your local codes.
See Figure 20 for recommended receptacle location.
WARNING
SHOCK HAZARD — Electrical Grounding Required.
Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
Never use an extension cord to connect power to
the unit.
Go on to 7 Level the Unit.
Leveling Information
Note: It is recommended that the unit is level.
1. Use a level to check the
levelness of the unit from
front to back and from
side to side. Level should
be placed along top edge
and side edge as shown
(see Figure 21).
2. If the unit is not level, adjust the feet on the corners of
the unit as necessary (see
Figure 22
).
3. Check the levelness after each adjustment and repeat
the previous steps until the unit is level. Go on to
8 Install the Unit
.
Installation Tip
If the room floor is higher than the floor in the cut-out
opening, adjust the rear feet to achieve a total unit rear
height of 1/8
"
less than the opening’s rear height. Shorten
the unit height in the front by adjusting the front feet.
This allows the unit to be gently tipped into the opening.
Readjust the front feet to level the unit after it is correctly
positioned in the opening.
6 Prepare Power Supply
23
-
1/8"
1-1/2"
7"
Figure 20
7 Level the Unit
Check
Level
Figure 21
Turn Feet to Adjust
Figure 22