02/2005 7 www.U-LineService.com
15R and 15WC Models
10. Fasten upper hinge to
unit (three screws).
Partially tighten screws.
See
Figure 11
.
11. Adjust door to assure
proper seal. Tighten
upper and lower hinge
screws securely.
12. Replace three plastic
plugs removed in Step 8
into holes on top of
unit. Replace screws in
holes in bottom of unit
on opposite side.
Stainless 15R Units and All 15WC Units
Note: The grille should not yet be installed. If it has been
installed, remove it for door reversing. See Page 11.
Stainless 15R Refrigerator
models and Black and
Stainless 15WC Wine Captain
models are reversible by
moving the hinge hardware
to the opposite side
(Figure 12) as follows:
1. Remove the top hinge
plate (three screws) from
cabinet and save.
2. Remove the bushing from
the top pivot plate’s post
and save. See
Figure 13
.
3. Being careful not to lose
the bottom pivot plate’s
bushing (
Figure 14
),
remove the door by lifting
it off the bottom hinge
bracket. Save the bushing.
4. Remove bottom hinge bracket from cabinet (two
screws). See
Figure 5
. Remove screws on opposite side
of cabinet (
Figure 6
). Note that there may be a nut
behind one or both screws on either side.
5. Install hinge bracket on
opposite side, bottom of
cabinet. See
Figure 7
.
Replace nut on back side
where installed. Align
hinge outer edge with
cabinet before tightening
screws.
6. Remove the top pivot
plate from the door (two
screws). Invert and install
it on the bottom of the
opposite side of the door.
7. Remove the bottom pivot plate from the door (two
screws). Invert and install it on the top of the opposite
side of the door.
8. Locate the bushing saved
in Step 3. Holding the
bushing in place, lift the
door onto the newly
located bottom hinge
bracket. See
Figure 14
.
9. Onto the new top pivot
plate’s post, assemble the
bushing saved in Step 2
and the hinge plate saved
in Step 1. Install three
screws to attach new top
hinge plate to cabinet.
10. Adjust door to assure proper seal.
Other Site Requirements
Power Supply
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A circuit (normal household current). See
Electrical Specifications on Page 10.
Environmental Requirements
The surrounding air temperature must be at least 50°F
(10°C) but must not exceed 110°F (40°C). Units may be
installed outdoors in a covered area. The unit must not be
located near heat-generating equipment or in direct
sunlight.
Figure 11
Hinge
Bracket
Hinge
Plate
Figure 12
Bushing
Pivot Plate
Door
Figure 13
Bushing
Pivot Plate
Door