from the main supply to your merchandiser. It
is most important that a voltage reading be
made at the compressor-motor electrical
connections, or as close to the compressor-
motor as possible, while the merchandiser is in
operation, to assure that the correct voltage
required by the compressor is being supplied.
Low or high voltage can detrimentally affect the
refrigeration unit and thereby void its warranty.
All merchandiser refrigerator electrical systems
are internally grounded. It is recommended
that a bonding braid be secured to the base of
the refrigerator and carried to a water pipe, to
complete the ground.
I. Installation Checklist
After the cabinet has been installed, leveled
and cleaned as described in the preceding
paragraphs, refer to the following checklist prior
to start-up.
Full voltage of the correct type, on a line
not affected by the operation of other
electrical appliances, must be available
for proper operation. Condensing units
are designed to operate with a voltage
fluctuation of plus or minus 10% of the
voltage indicated on the cabinet
electrical data plate. Burn-out of a
condensing unit due to exceeding the
high or low voltage limits will void the
factory warranty.
Leak check all exposed refrigeration
lines. Make sure refrigeration lines are
not dented, kinked or rubbing.
Check condenser fan for freedom to
rotate without striking any stationary
members.
Cabinet must be properly leveled.
Do Not become alarmed if a trace of
freon gas is detected in the internal
cabinet air. This may be due to
refrigerant used in expanding the foam
insulation used in this cabinet.
NOTE: All motors are lifetime oiled and
sealed. All self-contained models are
shipped from the factory with the
service valves opened ready for
operation.
J. Location of Serial Number/Data Plate
The serial data plate is mounted on the upper
left interior wall.
NOTE: When ordering replacement parts,
you must include the complete
cabinet model and serial numbers.