Victory Refrigeration VM-2 Refrigerator User Manual


 
SECTION 5
SERVICE
A. Servicing the Refrigeration Condensing Unit
The refrigeration condensing unit is serviceable from the front and rear of the merchandiser.
1. Discontinue power to merchandiser by turning arrow on temperature control knob to
“one” (1) and unplugging power cord from electrical outlet at rear of cabinet.
2. Remove front grill by lifting from bottom and pulling forward gently.
3. Take off rear grill by removing screws with phillips head screwdriver (*Note: remove four
(4) screws on VM-1; remove six (6) screws on VM-2 & VM-2SL).
4. Service required component.
*Important Note!: It is highly recommended that any service work outside the 3 month
condensing coil cleaning be performed by a “Victory” recommended
service company or qualified service technician.
5. After service work is complete, reverse previous steps and properly restore power.
B. Servicing Evaporator Fan Motors and Temperature Control
1. Discontinue power to merchandiser by turning arrow on temperature control knob to
“one” (1) and unplugging power cord from electrical outlet at rear of cabinet.
2. a. VM-1 Fan Panel/Drain Pan Disconnect
At the fan panel/drain pan assembly, remove temperature control knob and
screws with phillips head screws on both sides.
Let fan panel/drain pan assembly hang.
Proceed to “step 3”.
b. VM-2 & VM-2SL Fan Panel/Drain Pan Disconnect
Take hinged or sliding glass doors off cabinet.
Remove fluorescent light bulb and shield. Place in safe area.
Remove rest of light ballast assembly by unscrewing light rod and light rod
reflector.
17
Section 5 - Service
Section 5 - Service