Viking RRD0114 Oven User Manual


 
38
Basic specifications – Gas cooktopsBasic specifications – 7 Series gas rangetops
GAS 30" AND 36" WIDE COOKTOPS
Description VGC5305B VGC5366B
Overall width
30-3/4” (78.1 cm) 36-3/4” (93.3 cm)
Overall height from bot-
tom to top of grate
5” (12.7 cm)
Overall depth from rear
21” (53.3 cm)
Cutout width
28” (71.1 cm) minimum to
29-1/8” (74.0 cm) maximum
34” (86.4 cm) minimum to
35-1/8” (89.2 cm) maximum
Cutout height
2-3/4” (7.0 cm)
Cutout depth
19-1/8” (48.6 cm) minimum to 19-3/4” (50.2 cm) maximum
Gas requirements
Shipped Natural or LP/Propane, field convert with conversion kit (sold separately);
accepts standard residential 1/2” (1.3 cm) ID gas service line
Electrical requirements
120 V 60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product
Maximum amp usage
1.0 amps
Surface burner rating
Left front
Left rear
Center / Center front
Center rear
Right front
Right rear
18,000 Nat./16,500 LP (BTU) (5.4 Nat./4.9 LP (kw)
12,000 Nat./11,000 LP (BTU) (3.6 Nat./3.3 LP (kw)
12,000 Nat./11,000 LP (BTU) (3.6 Nat./3.3 LP (kw)
N/A
6,000 Nat./6,000 LP (BTU) (1.8 Nat./1.8 LP (kw)
8,000 Nat./7,000 LP (BTU) (2.4 Nat./2.1 LP (kw)
18,000 Nat./16,500 LP (BTU) (5.4 Nat./4.9 LP (kw)
10,000 Nat./9,000 LP (BTU) (3.0 Nat./2.7 LP (kw)
12,000 Nat./11,000 LP (BTU) (3.6 Nat./3.3 LP (kw)
12,000 Nat./11,000 LP (BTU) (3.6 Nat./3.3 LP (kw)
6,000 Nat./6,000 LP (BTU) (1.8 Nat./1.8 LP (kw)
8,000 Nat./7,000 LP (BTU) (2.4 Nat./2.1 LP (kw)
Approximate shipping
weight
67 lb. (30.2 kg) 80 lb. (36.0 kg)
7 SERIES GAS 36” AND 48” RANGETOPS
Description
VGRT736 VGRT748
Overall width
35-7/8” (91.1 cm) 47-7/8” (121.6 cm)
Overall height
To top of burner grate – 8 3/4” (22.2 cm)
To top of island trim – 9" (22.9 cm)
Gas manifold pressure
Natural 5.0” W.C.P./ Liquid Propane L/P 10.0” W.C.P.
Surface burner rating
Natural gas/LP
Front: (3) 23,000 BTU (6.7 kW) / 20,000 BTU (5.8 kW)
Rear: (2) 15,000 BTU (4.4 kW) / 13,500 BTU (4.0 kW)
(1) 8,000 BTU (2.3 kW) / 8,000 BTU (2.3 kW)
Front: (4) 23,000 BTU (6.7 kW) / 20,000 BTU (5.8 kW)
Rear: (3) 15,000 BTU (4.4 kW) / 13,500 BTU (4.0 kW)
(1) 8,000 BTU (2.3 kW) / 8,000 BTU (2.3 kW)
Approximate shipping
weight
150 lbs. (67.5 kg) 200 lbs. (90.7 kg)
Overall depth from rear*
To end of side panel – 25-1/4” (64.1 cm)
To end of knobs – 30” (76.2 cm)
*Add 3/4” (1.9 cm) to overall depth for models installed against a combustible wall.
Additions to Base Height
To top of backguard – add 10” (25.4 cm)
To top of high shelf – add 23-1/2” (59.7 cm)
Gas requirements
Shipped Natural or LP/Propane, accepts standard
residential 1/2” (1.3 cm) ID gas service line. Unit is
field convertible with proper conversion kit
Shipped Natural or LP/Propane, accepts standard
residential 3/4” (1.9 cm) ID gas service line. Unit is field
convertible with proper conversion kit
Electrical requirements
120VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to unit
Maximum amp usage
0.5 amps
* Please do not prepare installation from brochure data only. See installation instructions for important clearance/installation information.
* Please do not prepare installation from brochure data only. See installation instructions for important clearance/installation information.
37