Vulcan-Hart C24EA5 208/240V PRO Electric Steamer User Manual


 
MODEL C24EA - WATER LEVEL CONTROL COMPONENTS
F25213 (May 2006) Page 26 of 52
NOTE: Apply pipe thread sealant to plumbing
threads before assembly.
7. Reassemble parts removed in reverse order of
removal.
8. For Basic model steamers, perform ON/OFF
SWITCH ADJUSTMENT as outlined in ON/OFF
SWITCH.
9. Check steamer for leaks and proper operation.
MOTORIZED DRAIN VALVE
(PROFESSIONAL)
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1. Turn steamer off by using the on/off switch on
the front panel of steamer.
A. Allow steamer to complete drain cycle.
B. If motorized drain valve has malfunctioned
such that tank will not drain normally, refer
to Drain Tank Manually for draining
procedure.
Drain Tank Manually
1. Turn off water supply to steamer.
2. Disconnect power to steamer allowing time for
water in steam generator tank to cool to 140EF
before attempting to manually open drain valve.
3. Remove the RIGHT SIDE PANEL as outlined in
COVERS AND PANELS. Rear panel can also
be removed for added accessibility.
4. Locate the motorized drain valve found at lower
right side of steam generator tank.
5. Push in on the manual drain override knob to
disengage the gear set.
A. Rotate knob CW to manually open the
drain valve. Turning knob such that the slot
in knob is in a vertical orientation indicates
the drain valve is open. If slot in knob is in
a horizontal orientation, the drain valve is
closed.
B. Return manual drain override knob to the
closed position (slot in horizontal position).
Removal
1. Turn off water supply to steamer.
2. Remove the RIGHT SIDE PANEL as outlined in
COVERS AND PANELS. Rear panel can also
be removed for added accessibility.
3. Rotate body of motorized control assembly
CCW approximately 1/8 turn to disengage
assembly from drain valve.
4. Remove the motorized control assembly.
NOTE: The two electrical plugs on the motorized
control assembly are the same type connector. If the
electrical wiring is not connected correctly, the
motorized drain valve will not function.
A. Note location of electrical connections then
disconnect electrical wiring from motorized
control assembly.