C24EO SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS
2. Disconnect lead wires to component being
replaced.
3. Remove component.
4. Reverse procedure to install replacement
component and check steamer for proper
operation.
NOTE: If replacing temperature control, see
TEMPERATURE CONTROL CALIBRATION in
SERVICE PROCEDURES AND ADJUSTMENTS.
TIMER
1. Remove right SIDE PANEL.
2. Disconnect lead wires to timer.
3. Remove timer knob.
4. Remove rotary shaft seal from timer shaft and
remove timer.
5. Reverse procedure to install and check steamer
for proper operation.
HOLD THERMOSTAT
1. Remove right SIDE PANEL.
2. Remove lead wires and mounting nuts.
3. Remove hold thermostat.
4. Apply a small amount of thermal transfer
compound to the mating surface (disk side) of
the replacement thermostat.
A. Spread the compound completely and
evenly over the surface of the thermostat.
5. Reverse procedure to install and check steamer
for proper operation.
F25386 (June 2010) Page 6 of 24