HALF-SIZE GAS CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS
16
DOOR REVERSAL
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
1. Remove the door as outlined under “OVEN
DOOR”.
A. Remove the door strike plate from the top
of the door.
B. Rotate the door 180°. The top of the door
is now the bottom.
C. Install the door strike on the new top of the
door. Use the screws removed to install
the strike plate to fill the holes on the
bottom of the door.
2. Remove the bottom door bushing and anti-
rotation plate.
3. Remove the knockout from the lower sill cover.
4. Install the plug button in the old door bushing
hole in the lower sill cover.
5. Install the bottom door bushing and anti-
rotation plate.
6. Remove the catch assembly from the oven.
A. Move the door catch to the opposite side
of the door catch channel.
B. Install the door catch assembly to the
opposite side of the top sill.
7. Remove the door switch from the switch
mounting bracket.
A. Use the other set of holes in the mounting
bracket to mount the switch.
B. Place the switch insulation pad on the
mounting bracket.
C. Install the switch onto the mounting
bracket.
8. Install the door in the lower door bushing.
9. Install the top door bushing and door switch
mounting plate to the new position on the upper
sill.
10. Adjust the door as outlined under “DOOR
ADJUSTMENT”.
11. Adjust the door switch as outlined under
“DOOR SWITCH ADJUSTMENT”.
12. Replace the top front cover and check the oven
for proper operation.