Electrical
MODELS
TOTAL
KW
AMPERAGE
1 PHASE 3 PHASE
208V 240V 208V 240V 480V
VHX24E,
VHX24E5,
MHB24E
24 116 100 67 58 29
36 --- --- 100 87 44
42 --- --- 117 --- ---
48 --- --- --- 116 58
NOTES:
1. Amperage values in the table are
nominal. Tolerance is +5/-10%.
2. Voltage values are @ 60HZ.
3. 24KW 3 phase is standard for both
models. If a 24KW single phase
connection is needed, the machine is
field convertible at the terminal block.
See heating element circuit diagram
AI1388.
TOOLS
Standard
!
Standard set of hand tools.
!
VOM with AC current tester.
NOTE: Any quality VOM with a sensitivity of at
least 20,000 ohms per volt can be used.
Special
!
The recommended deliming chemical for the
water treatment system in use, for deliming of
the boiler.
!
Heat Exchanger Gasket (joint sealant strip,
Teflon) P/N 854058-1.
!
Loctite 242 thread sealant or equivalent
P/N 520228. Used on the top and bottom
cooking compartment door screws.
!
3/8 x 16 tap. Used for cleaning out threads on
front boiler flange.