— 4 —
Cord Connected Ovens
WARNING: THE ELECTRICAL CORD HAS A GROUNDING PLUG WHICH MUST BE CONNECTED
TO A PROPERLY GROUNDED RECEPTACLE. IF THE RECEPTACLE IS NOT THE PROPER
GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO NOT REMOVE THE GROUNDING PRONG
FROM THE PLUG.
ELECTRICAL DATA
Circuit Size (Minimum) & Fuse / Circuit Breaker Size (Maximum) compiled in accordance with the National Electrical Code (ANSI/
NFPA 70), 1993 Edition.
Model
Volts / Hz
/ Ph
Kilowatts Rated Amps
Circuit
Size
(Amps)
Fuse
Size or
Circuit
Breaker
Size*
(Amps)
90°
Copper
Wire Size
CB1824E 208/60/1 9.4 45.2 60 60 6
CB1824E 240/60/1 9.4 39.2 50 50 8
Per Phase Per Line Wire
L1 - L2 L2 - L3 L1 - L3 L1 L2 L3
CB1824E 208/60/3 5.2 1.6 2.6 32.5 28.3 17.5 40 40 8
CB1824E 240/60/3 5.2 1.6 2.6 28.2 24.5 15.2 40 40 8
* Dual Element Time-Delay Fuse or
Inverse Time Circuit Breaker