Vulcan-Hart VCE6H 126177 Oven User Manual


 
ELECTRIC COMBI OVENS - GENERAL
Page 5 of 68
Electrical
MODEL
POWER
(KW)
MACHINE AMPERAGE (3 PHASE/ 60HZ)
1
PER LINE
2
RECOMMENDED
CIRCUIT
PROTECTION
3
208V 240V 480V 208V 240V 480V
VCE6H
9 252211353015
VCE10H
18 50 43 22 70 60 30
VCE10F
18 50 43 22 70 60 30
VCE20H
24 67 58 29 90 80 40
VCE20F
36 100 87 43 125 110 60
NOTES:
1. Amperage values in the table are nominal. Tolerance
is +5/-10%.
2. Line currents must
be measured in full power
convection heat mode.
3. Complied in accordance with National Electric Code,
ANSI/NFPA 70, latest edition.
MODEL
INDIVIDUAL AMPERAGE (3 PHASE/ 60HZ)
1
CONVECTION HEAT
2
STEAM GENERATOR HEAT
3
ELEMENTS
208V 240V 480V
ELEMENTS
208V 240V 480V
KW NO. KW NO.
VCE6H
9 1 25 22 11 8 1 22 19 10
VCE10H
9 2 50 43 22 8 2 45 39 19
VCE10F
9 2 50 43 22 8 2 45 39 19
VCE20H
6 4 67 58 29 8 3 67 58 29
VCE20F
9 4 100 87 43 8 4 89 77 39
NOTES:
1. Amperage values in the table are nominal. Tolerance is +5/-10%.
2. Convection heater currents must
be measured in full power convection
heat mode.
3. Steam generator heater currents must
be measured in full power steam
mode.