VCH & VRT SERIES OVENS F-41162 (07-10)
9
8. Rotate the ADJ/SET Knob to
desired holding temperature.
9. Press the ADJ/SET Knob to
accept Hold Temp.
OPERATING:
1. Switch ON/OFF Switch to ON.
During the “Idle State/Time is blinking”:
2. Press and Hold the ADJ/SET
Knob for 3 seconds. The time
will no longer blink.
The Cabinet Temp. will display
“P-1” and is blinking.
3. Rotate ADJ/SET Knob to
desired pre-programmed cycle:
P-1 through 9.
4. Press Start Button.
You can push the ADJ/SET Knob any
time to abort the cycle and return to idle.
TESTING THE OVEN
Before using the oven for the first time,
verify that the oven operates normally.
1. Check that the oven is connected
to the correct power source.
2. Turn the oven ON at the power
switch.
3. Set the HOLD TEMP. to 140⁰F.
4. Check that the oven’s blower
motors/circulating fans, located at
the top of the oven, are
running.
The oven has cooling/exhaust fans
located at the left side of the unit.
These fans may not operate when the
oven is first turned on. The cooling
/exhaust fans only operate when the
thermostat to which they are connected
requires them to cool the electrical
components.
5. Check that the heating indicator
light is lit.
6. Check that the oven is warming
to the displayed holding
temperature.
7. Set the TIME to 2 hours.
Set the COOK TEMP. to 250⁰F.
Push the START Button.
8. Check that the COOK TEMP.
display has been blanked and the
HOLD TEMP. display is lighted.
9. Check the interior rear of the
oven to ensure that the oven is
heating.
If all of these functions perform
satisfactory, the oven is ready for
operation.
VENTILATION HOOD
REQUIREMENTS
Some local State Codes require the use
of a ventilation hood for equipment
operating in excess of 250⁰F. Many will
allow operation of Rethermalization
Ovens at lower temperatures. Please
contact a Service Agency to modify this
parameter, if needed to meet local State
Codes.