11
G. BYPASS HI-LIMIT THERMOSTAT
1. The hi-limit thermostat in this Belgian Waffle Baker has been found to be unnecessary. Wells
BWB-1S has been tested and approved by UL for use without the hi-limit thermosat.
2. All units requiring service, whether in or out of warranty, should have the hi-limit thermostat
bypassed.
3. With the power cord unplugged, remove wires
7 & 19 from the hi-limit thermostat (located in the
bottom grid).
4. Cut the push-on terminals from wires 7 & 19, as
close to the terminals as possible.
5. Remove 1/2” of insulation from the ends of wires
7 & 19. Connect the wires together using a ceramic
wire nut of the appropriate size.
6. Plug the waffle baker in, and test for proper
operation.
WIRING DIAGRAM
1
2
3
4
5
N.C.
N.O.
COM
1
2 3
4
5
6
white
black
green
L1
L2
1
2
10
17
11
14
16
9
15
TIMER
POWER CORD
CONNECTOR (2)
POWER
SWITCH
TEMPERATURE
CONTROLLER
4
3
7
8
12
20
6
13
TEMP.
SENSOR
LOWER
HEATING
ELEMENT
UPPER
HEATING
ELEMENT
5
MICRO
SWITCH
BUZZER
INDICATOR
LIGHT
VOLTS AMPS 1Ø
120 7.5 50/60 Hz
p/n 44867 Rev.D
7
19
HI-LIMIT
THERMOSTAT
7
19
CERAMIC
WIRE NUT