Whirlpool 30 eye-level range Double Oven User Manual


 
B. Strain relief required
LOCKING , II
INSERT FROM
UNDER FRAME
Disconnect clamping ring from strain relief. Push relief
(from bottom) through hole beneath terminal block.
Tighten clamping ring (from above) onto strain relief
threads.
W-m _--,.- is* ~l--T-i+..4
,_.~.,,. --L-n-U -I--Y.-w-
RUN CORD THROUGH
STRAIN RELIEF
Run cord or cable through strain relief.
Leave enough slack to attach ring-type terminals to
terminal block. Tighten clamping screws.
C. If frame grounding is allowed
SILVER COLORED
NEUTliAIv
1 ’ ’
Use this wiring method ONLY if local codes permit
connecting frame grounding conductor to neutral
wire of power cord.
THIS APPLIANCE IS MANUFACTURED WITH
NEUTRAL TERMINAL CONNECTED TO THE
FRAME.
If local codes do not permit grounding through the
neutral. The 3-conductor cord or cable assembly
must be replaced by a 4-conductor cord. The
replacement cord must be rated 240 volts, 50
amperes and investigated for use with ranges.
1.
2.
3.
4.
Connect neutral wire to the center silver-colored
terminal.
Connect remaining 2 wires to the terminals on either
side of the silver colored terminal.
Use ring type terminals only. Connect with the brass
nuts that are taped to the frame. Do not loosen fac-
tory installed nuts already on the terminal.
Replace terminal block cover.
D. 4-wire electrical connections
SILVER COLORED.
TERMINAL
i
y I”’
RELIEF :
Use this wiring method for mobile homes and
whenever a 4-wire installation is required.
1. Remove the grounding strap screw from the range
frame. Keep this ground screw. Bend up the ground-
ing strap so that it does not contact the range frame.
2. Connect the green ground wire to the frame of the
appliance with the ground screw, using the hole in
the frame where the ground strap was removed.
3. Connect the white neutral wire of the power cord to
the silver colored terminal of the terminal block. Con-
nect the remaining wires to the outer terminals.
4. Replace the terminal block cover.
5