Whirlpool 3189086 Cooktop User Manual


 
L.P gas conversion
Converting to L.P. gas should be done by
a qualified installer.
Fire Hazard
Shut off gas supply line valve.
Make all conversions before turning gas
supply valve back on.
Failure to follow these instructions can
result in explosion, fire or other injury.
J
Natural
A
n
Complete installation instructions,
Steps 1 - 9 before converting your cooktop to
L.P. gas.
Pressure regulator:
Use a wrench to unscrew the cap from the top
by turning counterclockwise. Turn the cap
over so the hole end is up. “L.P.” and “10”
W.C.” should be visible on face of cap.
Replace the cap and gasket on the regulator.
DO NOT REMOVE THE PRESSURE
REGULATOR.
pin
Natural gas y
increase gas
increase flame
size (Pre-set at
factory for
Natural gas)
Natural gas
conversion
Converting to Natural gas should be done
by a qualified installer.
Fire Hazard
Shut off gas supply line valve.
Make all conversions before turning gas
supply valve back on.
Failure to follow these instructions can
result in explosion, fire or other injury.
L.P.
Natural
A
n
Shut
off main gas supply line valve
and disconnect power supply cord before
converting your cooktop to Natural gas.
Pressure regulator:
Use a wrench to unscrew the cap from the top
by turning counterclockwise. Turn the cap
over so the hole end is down. “Nat.” and “6”
W.C.” should be visible on face of cap.
Replace the cap and gasket on the regulator.
DO NOT REMOVE THE PRESSURE
REGULATOR.
, hood
pin
\
L.P. gas
decrease gas
decrease flame
size
B
n
Turn the orifice hoods down until snua
against pin (approximately 2 to 2-l/2 turns).
DO NOT OVERTIGHTEN. The burner flames
cannot be properly adjusted if this conversion
is not made.
B
n
Loosen the orifice hoods away from
pins 2 to 2-l/2 turns. The burner flames
cannot be properly adjusted if this conversion
is not made.
C
n
After all the burners have been
converted to L.P. gas usage, complete Steps
C
n
After all the burners have been
10 - 13, Panel D.
converted to Natural gas, complete Steps
10 - 13, Panel D.
Adjusting for proper flame
Adjust the air shutters for proper flame by
sliding the air shutter to close or open the
shutter as needed. See Panel D, Steps
14-17. L.P. gas has a slightly yellow tip on top
of burner flames in addition to the other
proper characteristics.
Natural gas H
increase gas
increase flame size
(Pre-set at factory
for Natural gas)
A
4
l-4
L.P. gas
decrease gas
decrease
flame size
Adjusting for proper flame
Adjust the air shutters for proper flame by
sliding the air shutter to close or open the
shutter as needed. See Panel D, Steps
14-l 7. Natural gas does not have a yellow tip
to flame.
Panel E