STEP 3
ELECTRICAL CONNECTION
WARNING: Disconnect electrical supply before making
electrical connection. Failure to do so may result in
electrical shock or personal injury.
ELECTRICAL GROUND IS REQUIRED ON THIS
APPLIANCE
This appliance is manufactur;dwith the neutral terminal
connected to the frame.
1. If local codes permit connection of the frame
grounding conductor to the neutral wtre of the copper
power supply cord:
A. Remove the terminal block cover (lowest wire
cover).
B. The terminal nuts are taped to the frame below the
terminal block.
NOTE: Do not loosen factory installed nuts.
C. Connect the neutral wire of the copper power supply
cord to the center silver-colored terminal of the terminal
block and connect the other wires to the outer terminals,
See Figure 2.
Ring type terminals must be used on the copper power
supply cord wires.
D. Replace terminal block cover.
SILVER-COLORED
m LINE 2
GROUNDING
STRAP
NEUTRAL
(WHITE OR CENTER)
&b
e
AA-
-1
STRAIN RELIEF A
wy TO FUSED
DISCONNECT BOX
OR APPROVED
WIRING DEVICE
H COPPER
POWER SUPPLY CORD
(40 AMPERES)
FIGURE
2. If local codes DO NOT permit frame qroundinq to the
neutral wire of the copper power supply cord:
A. Remove terminal block cove1
B. Remove the ground strap from the terminal block
and from the appliance frame. Ret;lln the ground
screw.
C. Connect the neutral wire of the copper power supply
cord to the center silver-colored terminal of the terminal
block and connect the other wires to the outer terminals.
See Figure
3. Ring-type terminals must be used on the
copper power supply cord wires.
D. Connect a separate insulated green-colored copper
grounding wire (No. 8 mlnimum) to a grounded cold
water pipe* by means of a clamp, and then to the frame
of the appliance with the grounding screw, using the
hole in the frame where the grounding strap was re-
moved. See
Figure
3. Do Not ground to a gas supply
pipe or hot water pipe. Do Not connect the copper power
supply cord to electric power until appliance IS perma-
nently grounded. See Figure 4.
E. Replace terminal block cover.
E2
/ POWER SUPPLY CORD
(40 AMPERES)
POWER SUPPLY
CORD.
FIGURE 3
‘Cold water pope must have metal cont~nu~ry to electrlczl
ground and not be Interrupted by plastic, rubber or other
- electrically lnsulatang connectors (ancludlng water meter or
pump) without adding a jumper uure at these connectlons.
TO APPLIANCE FRAME
BARE OR NO. 8 GREEN
INSULATED COPPER
GROUNDING WIRE
COPPER
GROUNDING WIRE
REMOVE
(AlTACH TO GROUNDED
ON PIPE. TIGHTEN NUTS FIRMLY. COLD WATER PIPE.)
FIGURE 4