DISTRIBUTION OF L.P. GAS
For Liquid Propane (L.P.) gas, appliances generally operate on gas pressure rated at between 10
and 12 inches water column pressure. Each appliance usually has its own pressure regulator to
more accurately meet the designed requirements (see Figure 1-8).
Service
Regulator
L.P. Gas Main 28
"
WCP (1 lb.)
10
" -
12
"
WCP In-House Gas Supply Line
Water
Heater
Range
Furnace
Dryer
L.P. Gas Tank
Appliance
Regulator
10
"
Figure 1-8