Whirlpool W10102500A Dishwasher User Manual


 
Option 2, Power supply cord method
The power cord and connections must comply with the
National Electrical Code, Section 422 and/or local codes
and ordinances. Recommended power cord length is
54" min. and 64" max.
1. Remove terminal box cover.
2. Connect incoming power cord white (or ribbed) wire to
dishwasher white wire, black (or smooth) wire to black
wire and ground wire to dishwasher green wire. Use UL
listed wire nuts of the appropriate size for connections.
3. Replace terminal box cover. Make sure wires are not
pinched under the cover.
4. Plug power cord into a grounded 3 prong outlet.
5. Check the power supply cord does not touch
dishwasher motor or lower part of dishwasher tub.
Connect to water supply
Helpful Tip:
Compression fittings:
a. Slide nut onto copper tubing about 1" (2.5 cm).
b. Slide ferrule onto the tubing. Do not position ferrule
on the end of the tubing.
c. Put the tubing into the elbow as far as it will go.
d. Slide the nut and ferrule forward and start the nut
onto the elbow threads. Be gentle when handling
and positioning the copper tubing, it bends and kinks
easily.
1. To prevent vibration during operation, route the water
supply line so that it does not touch the dishwasher
base, frame or motor.
nut
ferrule
elbow
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
2. Pull direct wire through hole in terminal box.
Helpful Tip:
• Select the proper size twist-on
connectors to connect your household
wiring to 16-gauge dishwasher wiring.
• Insert wire ends into twist-on
connector. Do not pre-twist bare wire.
• Twist connector.
• Gently tug on wires to be sure both
are secured.
3. Connect the wires as follows using twist-on connectors
sized to connect direct wire to 16-gauge dishwasher
wire:
4. Tighten clamp connector or conduit connector screws.
5. Reinstall terminal box cover with wires inside terminal
box.
The cover must be outside the box on the left side.
6. Make sure no wires are pinched by cover.
black
white
ground
Terminal box wire:
white
black
ground connector
Power supply wire:
white
black
ground wire
12
terminal
box cover