13
WARNING
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green ground connector
in terminal box.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Ground
wire
Power Supply Cord—
Connect ground wire
2
Ground
wire
Washer
Ground
connector
Power Cord—Connect
remaining wires
3
Terminal box wire:
white
black
ground connector
Power supply wire:
white
black
ground wire
Wiring configuration
If needed, see website for animated representation of this
step. Visit www.whirlpool.com under FAQ tab.
Tighten strain relief screws to secure cord.
Power Cord−Secure cord
on strain relief
4
Place wires inside terminal box. Insert tabs
on left side of cover. Make sure wires are tucked inside
box. Close cover ensuring wires are not pinched. Use ¹⁄₄"
nut driver and previously removed screw to secure
cover.
NOTE: Do not plug into outlet until instructed to do so.
Power Cord—Reinstall
terminal box cover
5
Measure cabinet opening
1
Determine Cabinet Opening
NOTE: Twist on wire connector. Gently tug on wires to be
sure both are secured.
Connect wires black to black and white to white, using UL
Listed/CSA Approved twist-on wire connectors (included
with power supply cord kit).
Remove the green grounding screw and place
through the ring terminal of the green ground wire.
Reattach and tighten the green screw.