Whirlpool W10526071A Double Oven User Manual


 
5
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
Range may be installed with zero clearance to combustible
construction at the rear and on the sides below the cooktop.
*Drill on centerline 1¼" (3.1 cm) from rear wall for gas supply line.
**Gas lines must be installed within the shaded area to ensure
proper alignment of this oven with cabinets.
***Electrical plugs must be installed within the shaded area to
ensure proper alignment of this oven with cabinets.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
Electrical Requirements
IMPORTANT: The range must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is
required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this range be provided.
Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that
the outlet provides 120-volt power and is correctly grounded.
The wiring diagram is located on the back of the range in a
clear plastic bag.
A.18" (45.7 cm) upper cabinet to countertop
B.13" (33.0 cm) upper cabinet depth
C.30" (76.2 cm) min. opening width
D.For minimum clearance to the top of the cooktop, see NOTE.
E.30" (76.2 cm) min. opening width
F. 3" (7.6 cm) min. clearance from both sides of the range to the side
wall or other combustible material.
G.Cabinet door or hinges should not extend into the cutout.
H.3" (7.6 cm) distance from wall
I.1¹⁄₂" (3.8 cm) min. from right side cabinet
J.8" (20.3 cm) width
K.7" (17.8 cm) min. from floor
L.2" (5.1 cm) min. from floor
B
D
C
E
A
F
G
8½"
(21.6 cm)
14"
(35.6 cm)
8½" (21.6 cm)**
gas line location
1½"
(3.8 cm)
1¼"*
(3.1 cm)
2¼" (5.7 cm)
H
I
J
K
L
***
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING