WOLF PRO WALL CHIMNEY VENTILATION HOODS
Do not remove the control knob bezel to
access hood wiring; this will damage the
bezel assembly.
Location of wiring
IMPORTANT
NOTE
You must follow
all National
Electrical Code
regulations. In
addition, be aware
of local codes and
ordinances when
installing your
service.
INSTALL WIRING
Risk of electrical shock. This ventilation
hood must be properly grounded. This
unit should be installed by a qualified
electrician in accordance with all applica-
ble national and local electrical codes and
standards.
Before servicing or cleaning unit, switch
power off at service panel and lock the
service disconnecting means to prevent
power from being switched on acciden-
tally. When the service disconnecting
means cannot be locked, securely fasten a
prominent warning device, such as a tag,
to the service panel.
INTERNAL BLOWER WIRING
Remove the hood electrical box cover.
Run power cable to the installation location.
Insert the power cable into the electrical
box by running it through the wire clamp
previously installed. Tighten the wire clamp
to secure the cable. Refer to the illustration
below for the location of the electrical box.
Using the supplied wire connectors, connect
wires as follows: BLACK wire from hood to
power supply BLACK wire, WHITE wire
from hood to power supply WHITE wire and
GREEN or BARE wire from power supply to
GREEN ground screw in the electrical box.
Place all wiring connections inside the
electrical box and reinstall the cover. Make
sure that the wires are secure and that no
wires are pinched between the cover and
box.
When making electrical connections, make
sure the electrical power is turned off at
the power source or circuit breaker before
proceeding.
Risk of electrical shock. Do not remove
the wire connector on the ORANGE wire
from the hood.
Location of Knockout for Wiring
Model Hood Width (A)
PWC362418(R) 36" (914) 2" (51)
PWC422418(R) 42" (1067) 3" (76)
PWC482418(R) 48" (1219) 4" (102)
PWC542418(R) 54" (1372) 4" (102)
Letter (A) corresponds to the illustration.