Wolf Appliance Company L402212 Ventilation Hood User Manual


 
6
WOLF PRO VENTILATION HOOD LINERS
INSTALLATION SPECIFICATIONS
The illustration and chart below provide
dimensions critical for proper installation of
t
he Pro hood liner.
Pro Hood Liners
Model (A) (B) (C) (D)
L342212 34
3
/8" (873) 9
3
/8" (238) 17
3
/16" (437) 6" (152)
L402212 40
3
/8" (1026) 9
3
/8" (238) 20
3
/1
6
" (513) 6" (152)
L462212 46
3
/8" (1178) 9
3
/8" (238) 23
3
/1
6
" (589) 6" (152)
L522212 52
3
/8" (1330) 9
3
/8" (238) 26
3
/16" (665) 6" (152)
L582212 58
3
/8" (1483) 9
3
/8" (238) 29
3
/16" (741) 6" (152)
Letters correspond to those in the illustration.
A
WIDTH OF
HOOD LINER
D
C
TO CENTER
OF TRANSITION
TO CENTER
OF TRANSITION
B
HEIGHT OF
TRANSITION
DECORATIVE HOODS
A decorative hood can be created out of wood,
plaster, tile or metal. The shape of the decora-
t
ive hood is not critical. The only place where
the hood liner and outside cover must meet is
at the bottom edge of the liner. The decorative
h
ood and liner must fit at the bottom edge in
both width and depth.
The height of the hood liner does not have to
be the same as the height of the decorative
hood and is generally shorter.
The top depth of the hood liner, which is 12"
(305) standard, must be less than the interior
depth of the decorative hood. Measure the
interior depth of the hood at the top height of
the liner to make sure the liner will fit inside
the decorative hood.
The hood liner comes standard with a 4" (102)
lower reveal. Be sure to include this dimension
in your decorative hood selection.
Always use the interior measurements of the
decorative hood and measure in multiple
places. Use the smallest dimensions to verify