Wolf Appliance Company Pro Wall Ventilation Hood User Manual


 
Pro Wall Hood Specifications 8
Discharge Specifications
LOW-PROFILE WALL HOODS
The illustrations provide dimensions for discharge options
for low-profile wall hoods. These dimensions are critical
for proper installation. Dimension A in the illustrations will
vary with the width of the hood. Refer to the chart below.
IMPORTANT NOTE: The transition included with the 500
CFM internal blower accommodates 3
1
/4" (83) x 10" (254)
ductwork. An optional 3
1
/4" (83) x 10" (254) to 8" (203)
round transition is available through your authorized Wolf
dealer. For local dealer information, visit the find a
showroom section of our website, wolfappliance.com.
Low-Profile Wall Hoods
WIDTH OF HOOD A
30" (762) 14
3
/4" (375)
36" (914) 17
3
/4" (451)
42" (1067)* 20
3
/4" (527)
48" (1219)* 23
3
/4" (603)
*500 CFM blower not available for these hood widths.
A
TO
CENTER OF
TRANSITION
1
1
/2"(38)
2"(51)
TO CENTER
OFTRANSITION
Horizontal discharge.
9"
(229)
5
5
/8"(143)
TO CENTER
OFTRANSITION
A
TO
CENTER OF
TRANSITION
Vertical discharge with accessory transition.
1
1
/2"(38)
2
5
/8"(60)
TO CENTER
OFTRANSITION
A
TO
CENTER OF
TRANSITION
Vertical discharge.
LOW-PROFILE WALL HOODS DISCHARGE OPTIONS
DISCHARGE
CUT-OUT
3
1
/4
"
(83)
14"
(356)
Cut-out without transition.