Zanussi ZCM 630 Range User Manual


 
22
BURNER ULTRA-RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 3.5 1.2 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE m
3
/h 0.333 0.114 0.190 0.043 0.095 0.031
NOZZLE REFERENCE 136 Adjust. 96 Adjust. 70 Adjust.
NOMINAL THERMAL
POWER kW 3.5 1.2 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE g/h 252 86.5 144 32 72 24
NOZZLE REFERENCE 93 56 71 32 50 28
NATURAL GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
Important Safety Requirements
This appliance must be installed in accordance with the
Gas Safety (Installation and Use) Regulations (current
addition) and the I.E.E. Wiring Regulations. Detailed
recommendations are contained in the following British
Standard Codes of Practice - B.S. 6172, B.S. 5440: Part
2 and B.S. 6891: Current Editions.
Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY
: II 2H3+
APPLIANCE GAS SUPPLY: Natural gas G20 20mbar
Dimensions
Height 900 mm
Depth 600 mm
Width 600 mm
Oven Capacity 1.8 Cu. ft
Hob
Rear right burner (semi-rapid) 2,000 W
Front right burner (auxiliary) 1,000 W
Rear left burner (semi-rapid) 2,000 W
Front left burner (ultra-rapid) 3,500 W
Technical Data
Instructions for the Installer
Oven
Top heating element 1,045 W
Bottom heating element 1,250 W
Grill Element 1,880 W
Convection heating element 2,090 W
Convection fan 30 W
Oven light 15 W
Total rating 2,315 W
Supply voltage (50 Hz) 230-240 V
Provision for Ventilation
The room containing the cooker should have an air supply
in accordance with B.S. 5440: Part 2: Current Editions.
The following requirements for ventilation must be met.
The cooker should not be installed in a bed sitting room
with a volume of less than 20m
3
, if it is installed in a
room of volume less 5m
3
an air vent of effective area of
110cm
2
is required; if it is installed in a room of volume
between 5m
3
and 10m
3
, an air vent of effective area 50cm
2
is required, while if the volume exceeds 11m
3
no air vent
is required. However, if the room has a door which opens
directly to the outside, no air vent is required even when
the volume is between 5m
3
and 11m
3
.