Zanussi ZCM 630 Range User Manual


 
27
Conversion from Natural to LPG
Gas
IMPORTANT
The replacement/conversion of the gas hob should
only be undertaken by a CORGI registered engineer.
It is important to note that this model is designed for use
with natural gas but can be converted for use with butane
or propane gas providing the correct injectors are fitted.
The gas rate is adjusted to suit.
Method
Ensure that the gas taps are in the 'OFF' position
Isolate the hob from the electricity supply
Remove all pan supports, burner caps, rings, crowns
and control knobs.
With the aid of a 7mm box spanner the burner injectors
can then be unscrewed and replaced by the
appropriate LPG injectors (see Table: page 22).
TO ADJUST THE GAS RATE
With the aid of a thin bladed screwdriver completely
tighten clockwise the by pass screw. Upon completion
stick the replacement rating plate near the gas supply
pipe.