Zanussi ZGL62IT Cooktop User Manual


 
Hob recess dimensions
Width: 550 mm
Length: 470 mm
Heat input
Rapid burner: 3.0 kW
Semi-rapid burner: 2.0 kW
Auxiliary burner: 1.0 kW
TOTAL POWER: G20 (2H) 20 mbar = 8 kW
G30 (3+) 28-30 mbar =
567 g/h
G31 (3+) 37 mbar = 557
g/h
Electric supply: 230 V ~ 50 Hz
3 core flexible cable with
non rewireable plug fitted
with a 3 amp cartridge
fuse
Gas connection: R 1/2 "
Category: II2H3+
Gas supply: G20 (2H) 20 mbar
Appliance class: 3
By-pass diameters
Burner Ø By-pass in 1/100 mm.
Auxiliary 28
Semi-rapid 32
Rapid 42
Gas burners
BURNER NORMAL
POWER
REDUCED
POWER
NORMAL POWER
NATURAL GAS
G20 (2H) 20 mbar
LPG
(Butane/Propane) G30/G31 (3+)
28-30/37 mbar
kW kW inj. 1/100
mm
m³/h inj. 1/100
mm
g/h g/h
G30 G31
Auxiliary
burner
1.0 0.33 70 0.095 50 73 71
Semi-rapid
burner
2.0 0.45 96 0.190 71 145 143
Rapid burn-
er
3.0 (nat. gas)
2.8 (LPG)
0.75 119 0.286 86 204 200
Environment concerns
The symbol on the product or on its packaging
indicates that this product may not be treated as
household waste. Instead it should be taken to the
appropriate collection point for the recycling of electrical
and electronic equipment. By ensuring this product is
disposed of correctly, you will help prevent potential
negative consequences for the environment and human
health, which could otherwise be caused by inappropriate
waste handling of this product. For more detailed
information about recycling of this product, please contact
11