1 2
3
4
5
1 Green and Yellow
2 3 amp fuse
3 Brown
4 Cord clamp
5 Blue
Should the plug need to be replaced for any reason, the
wires in the mains lead are coloured in accordance with
the following code:
Green and Yellow - Earth
Blue - Neutral
Brown - Live
1. Connect the green and yellow (earth) wire to the ter-
minal in the plug which is marked with the letter 'E' or
the earth symbol
or coloured green and yellow.
2. Connect the blue (neutral) wire to the terminal in the
plug which is marked with the letter 'N' or coloured
black.
3. Connect the brown (live) wire to the terminal in the
plug which is marked with the letter 'L' or coloured
red.
Upon completion there must be no cut, or stray strands of
wire present and the cord clamp must be secure over the
outer sheath.
Important! A cut off plug inserted into a 13 amp socket is
a serious safety (shock) hazard. Ensure that the cut off
plug is disposed of safely.
Important! The replacement of electric cable must be
carried out exclusively by the service force centre or by
personnel with similar competencies, in accordance with
the current regulations.
Replacement of the connection cable
To replace the connection cable use only H05V2V2-F T90
or equivalent type. Make sure that the cable section is ap-
plicable to the voltage and the working temperature. The
yellow/green earth wire must be approximately 2 cm lon-
ger than the brown (or black) phase wire.
Building In
min. 55 mm
min. 650 mm
550 mm
min. 600 mm
min. 600 mm
30 mm
470 mm
B
A
A - supplied seal
B - supplied brackets
6