Zanussi ZHC 590 Ventilation Hood User Manual


 
16
INSTALLING THE COOKER HOOD
Ducting Connection
Connect the ducting chosen to:
• the Ø150mm ducting spigot on top of the motor
housing, or the Ø150-120mm ducting spigot item 9
and secure using the jubilee clips item 25.
A Ø120-125mm collar item 9a is provided to t over
the Ø120mm ducting spigot when 125mm ducting is
tted.
If the room where the cooker hood is to be used
contains a fuel burning appliance such as a central
heating boiler, then its ue must be of the room
sealed or balanced ue type.
If other types of ue or appliances are tted sure
that there is an adequate supply of air to the
room.
The cooker ducting (extraction mode) must never
be connected to central heating ues, radiators or
water heaters etc.
Recirculation
The cooker hood is supplied speci ed for use in the
recirculation mode, with the charcoal lter tted.
In the recirculation mode contaminated air is passed
through the charcoal lter to be puri ed and recirculated
into the kitchen through the grille outlets on either side
of the chimney.
Recirculation Connection
• Insert reducer ange 9 on the extractor outlet.
• Push t connector 15 onto the reducer ange.
Insert extension piece 14.2 sideways into connector
15 making sure that the outlet corresponds with the
mouth of the chimney
9 + 9a
ø 125ø 150
15
9
14.2