INSTALLATION INSTRUCTIONS
It is dangerous to alter the specifications or attempt to modify this product in any way.
Technical information
DIMENSIONS HEIGHT OF CANOPY: (incl glass visor) 46mm
HEIGHT OF CHIMNEY: (UPPER SECTION) 215mm
(LOWER SECTION) 740mm
WIDTH OF CANOPY: (incl glass visor) 898mm
DEPTH OF CANOPY: (incl glass visor) 700mm
ELECTRICAL SUPPLY VOLTAGE: (~50Hz) 230V
POWER CONSUMPTION: 230W
FAN MOTOR: 150W
LAMPS: (4x20W) 80W
SUITABLE FOR -
INSTALLATION ABOVE: ELECTRIC HOB: 7KW (MAX)
GAS HOB: 10KW (MAX)
SLOT-IN ELECTRIC COOKER: 12.4KW (MAX)
SLOT-IN GAS COOKER: 13.5KW (MAX)
DOUBLE INSULATED DO NOT EARTH
Electrical Requirements
Any permanent electrical installation must
comply with the latest I.E.E. Regulations and
local Electricity Board regulations. For your own
safety this should be undertaken by a qualified
electrician e.g. your local Electricity Board, or a
contractor who is on the roll of the National
Inspection Council for Electrical Installation
Contracting (NICEIC).
Electrical Connection
Before connecting to the mains supply ensure
that the mains voltage corresponds to the
voltage on the rating plate inside the cooker
Note: CE Marking certifies that this appliance complies with the
requirements laid down in EEC directive 89:336 (Electromagnetic
compatibility) and subsequent modifications and Low Votage directive
72/23/E.
This appliance is fitted with a 2 core mains
cable and must be permanently connected to
the electricity supply via a double-pole switch
having 3mm minimum contact gap on each
pole. A Switched Fuse Connection Unit to
BS.1363 Part 4, fitted with a 3 Amp fuse, is a
recommended mains supply connection
accessory to ensure compliance with the Safety
Requirements applicable to fixed wiring
instructions.
This appliance conforms to BS.800:1988 and
EEC Directive No. 78 308 regarding
suppression of radio and television interference.
9
INSTALLING THE COOKER HOOD
Unpacking
The hood is supplied with the following
components for installation as illustrated.
Item Qty Description
1 1 Hood body, complete with:
Controls, lighting, blower and
filters
2 1 Telescopic chimney comprising:
2.1 1 Upper section
2.2 1 Lower section
7.1 1 Telescopic frame complete with
extractor, consisting of:
7.1a 1 Upper frame
7.1b 1 Lower frame
8a 1 Right-hand air outlet grille
8b 1 Left-hand air outlet grille
9a 1 Ø120-125mm Ducting collar
9b 1 Ø150-120mm Ducting spigot
14 1 Recirculation extension ducting
14.1 2 Recirculation extension ducting
15 1 Recirculation spigot
24 1 Junction box
25 2 Jubilee Clips
Item Qty Installation Components
12c 6 Ø2.9 x9.5mm Chimney fixing
screws
12e 2 Ø2.9 x6.5mm Junction box
fixing screws
12f 4 M6x10mm Hood body fixing
screws
12g 4 M6x80mm Lower frame fixing
screws
12h 4 Ø5.2x70mm Upper frame fixing
screws
21 1 Ceiling drilling template
Item Qty Documents
1 Instruction Manual
10
7.1a
7.1
22
23
12h
7.1b
2
2.1
2.2
8b
8a
12c
11
21
12g
12f
25
24
12e
12c
14.1
15
9
14
12c
1