CS 3216 Operators Manual 31
PROPORTIONAL BAND 1
POLL:
31 24
SELECT:
31 25
FORMAT:
Numeric
UNITS:
ºF
DESCRIPTION:
Proportional band for the primary control output in degrees
RESET 1 (INTEGRAL)
POLL:
31 28
SELECT:
32 29
FORMAT:
Numeric
UNITS:
Seconds
DESCRIPTION:
Reset time for the primary control output in seconds (Integral term).
RATE 1 (DERIVATIVE)
POLL:
31 2A
SELECT:
32 2B
FORMAT:
Numeric
UNITS:
Seconds
DESCRIPTION:
Rate time for the primary control output in seconds (Derivative term).
ALARM 1 SETPOINT
POLL:
31 2C
SELECT:
31 2D
FORMAT:
Numeric
UNITS:
ºF
DESCRIPTION:
Temperature at which the first configured 3200 alarm is activated/deactivated.
ALARM ACTIVE STATUS
POLL:
31 2E
SELECT:
N/A
FORMAT:
Status
UNITS:
None
DESCRIPTION:
Set to ‘1’ if there are any alarms active, otherwise 0.
ALARM 2 SETPOINT
POLL:
31 32
SELECT:
31 33
FORMAT:
Numeric
UNITS:
ºF
DESCRIPTION:
Temperature at which the second configured 3200 alarm is activated/deactivated.