DOC. NO. 5956.677.00 P. 20 / 30
Press the START and ENTER buttons together to display of the first Apex warning in progress. The possible
Apex low level warnings are:
Probe failed:
ALr Prb FLt
The conductivity probe reading is outside the permissible reading range.
Probe missing:
ALr Prb MiS
The conductivity probe is disconnected.
Checksum error:
ALr CHS Err
There is no matching between the checksum saved in the APEX memory and that calculated by the firmware.
Rinse pump motor was shorted:
ALr Rin sHr
The rinse aid peristaltic pump motor is short-circuited.
Detergent manager on:
dEt MAn On
The Detergent manager function is operational.
Rinse manager on:
rin MAn On
The Rinse manager function is operational.
Below detergent set point:
BEL dEt SEt
The concentration of detergent in the tank is lower than the set point value.
Use the drain and de-lime buttons to scroll the low level warnings. When the last warning is reached, press the drain button to display the
following read-only parameters:
Total dissolved solid:
tdS
This parameter displays the current total dissolved solids.
Detergent set point offset:
OtS
This parameter displays the conduttivity offset of the supply water.
Raw conductivity:
CrA
This parameter shows row (not temperature compensated) probe conductivity readings.
Compensated conductivity:
CAd
This parameter shows temperature compensated probe conductivity readings.
Wash temperature:
ttH
This parameter shows dish machine wash temperature readings (conductivity probe temperature sensor).
If there are no warnings in progress, the first read-only parameter appears when accessing the Apex data mode.