C1.3 PARAMETRI DI CONFIGURAZIONE
Inverter Telemecanique AH var 11 type ATV11PU12M2E380
Parameters for 110Vac gearmotor (Delta connection)
Parameter Description Standard machine
ACC Acceleration ramp time 3.0
dEC Deceleration ramp time 0.5
LSP Low speed 0.0
HSP High speed 100
ItH Motor thermal current 3.6
SP2 2nd preset speed 10
SP3 3rd preset speed 25
SP4 4th preset speed 50
Alt Act Scale of analog input 10U
drC UnS Nominal motor voltage 110
FrS Nominal motor frequency 50
StA Frequency loop stability 20
FLG Frequency loop gain 50
UFr Ir compensation 50
nCr Nominal motor current 3.6
CLI Current limit 3.9
nSL Nominal motor slip 5
SLP Slip compensation 100
COS Nominal motor cosine 0.65
FUn tCC ACt Type of control 2C
tCt Type of two wire control Lel
rrS Reverse nO
Ps2 LIA Preset speed lia nO
LIB Preset speed lib nO
HSP LIA Config. input Lia nO
LIB Config. input Lib nO
tLS 0.0
PI PIF nO
LOC Overload threshold 90
tOL Time delay for overl. func. 0
API Histeresis freq. reached 0.3
LUL Underload threshold 60
tUL Time delay for underl. func. 10
rSF Fault reset nO
rP2 LI Second ramp nO
LC2 LI 2nd limit current nO
nST Freewheel stop nO
StP Controlled stop on loss of line FST
brA Deceleration ramp adaptation YES
AdC ACt Automatic dc injection YES
tdC Injection time on stopping 0.5
SdC Injection current 2.9
SfT ACt Frequency range LF
Sfr Switching frequency 4
FLr Catch on the fly nO
dO ACt Analogic output do OCr
Atr Automatic restart nO
bFr Motor frequency 50
SCS Configuration backup nO
FCS Reminder of the configuration nO