Error message E-5 display reads HI.
Error message E-6.
Error message E-10.
Error message E-41.
Read display temperature - if display
temperature reads HI, unplug power
connector from control board. If secondary
contactor stays engaged, change contactor -
if secondary contactor disengages, change
control board. If shortening temperature
reads normal - defective thermal sensor -
replace.
Defective thermal sensor.
Replace thermal sensor.
Reset manual high limit thermostat.
Depress timer switch.
Control must be completely reprogrammed.
If the power connector is making poor contact onto the board, an error message could be
read, or it might disable other components. When removing connector, look down into power
connector to see if the ramp connectors, inside the power connector, are not flat. If so,
they can be removed from the power connector, and bent back into proper position.