A SERVICE OF

logo

Commands 73
Commands
10-Byte version
CDB Fields:
Specific Status:
Following a successful Mode Select command, Unit Attention status is posted to
all initiators other than the initiator of the Mode Select command. The sense
1
Reserved (0) PF Reserved (0) SP (0)
2
Reserved (0)
3
Reserved (0)
4
Parameter List Length
5
Control
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
0
Operation Code (55h)
1
Reserved (0) PF Reserved (0) SP (0)
2
(MSB)
Reserved (0)
6
(LSB)
7
(MSB)
Parameter List Length
8
(LSB)
9
Control
PF Page Format
0The MODE SELECT parameter data is not SCSI-2 mode page compatible. Only the
parameter header and block descriptor may be sent.
1 The parameter data is SCSI-2 mode-page compatible.
SP Save Pages
0 This bit is not supported and must be zero.
Parameter List
Length
0 No data is transferred.
>0 The length in bytes of the
MODE SELECT parameter list to be transferred.