Troubleshooting108
2092 Open Right Door Fault
(Door open sensor time-out detected
when open door.)
• Press the Enter button to clear the
message.
• Cycle power to the library or reboot
using the GUI touch screen.
• Run sensor test.
• Make sure door(s) are closed.
2093 Open Doors Fault
(Door open sensor time-out detected
when open door.)
• Press the Enter button to clear the
message.
• Cycle power to the library or reboot
using the GUI touch screen.
• Run sensor test.
• Make sure door(s) are closed.
2094 Open DLT Handle Fault
(Failed to open DLT handle.)
• Press Enter to clear the message.
• Cycle power to the library or reboot by
using the LCD touch display
• Make sure the drive shows good status
through the drive status window.
20a0 No IP Address Found
(SMC router failed to get an IP address.)
• Press the Enter button to clear the
message.
• Ensure network configuration options are
set correctly.
• Cycle power to the library or reboot
using the GUI touch screen.
20a1 No IP Address Mode Fault
(SMC router failed to detect static or IP
address mode.)
• Press the Enter button to clear the
message.
• Ensure network configuration options are
set correctly.
• Cycle power to the library or reboot
using the GUI touch screen.
20b0 Unknown Exchange For The Async
message
(Unexpected exchange detected when
process messages.)
• Press the Enter button to reboot.
• Cycle power to the library or reboot
using the GUI touch screen. Wait 30
seconds to power up again.
Table 10 Fault Symptom Codes (continued)
FSC Message ERP